Are you having issues? Select the issue you are having below and provide feedback to HumidCalc.
Complete guide to troubleshoot HumidCalc app on iOS and Android devices. Solve all HumidCalc app problems, errors, connection issues, installation problems and crashes.
Table of Contents:
Some issues cannot be easily resolved through online tutorials or self help. So we made it easy to get in contact with the support team at yoshihito sakagami, developers of HumidCalc.
Furthermore, HumidCalc calculates the air condition from dry-bulb temperature(Td) and wet-bulb temperature(Tw) obtained by Assmann-Psychrometer, etc. , and HumidCalc can also input atmospheric pressure. Even if you enter the measurement value such as a non-draft type psychrometer(for example, "Augusto Psychrometer", etc. ), just tap the button and the corresponding value can be displayed (※ HumidCalc is subject to use of a ventilation type psychrometer in terms of measurement accuracy). HumidCalc can calculate 11 items and 13 indicators, and conversion to the Celsius temperature and SI units (or in the Fahrenheit temperature and Imperial and US customary measurement systems) also you can simply by switching of "Temperature Unit". If you want to get the current atmospheric pressure, the current dry-bulb temperature(Td) and the current wet-bulb temperature(Tw), tap the "Weather" information button. The calculation formula of the outdoor WBGT is "WBGT = 0. 7 Tnw + 0. 1 Td + 0. 2 Tg", but since there is no entry a item Globe thermometer temperature(Tg) in HumidCalc , so estimation the Globe thermometer temperature(Tg) by Dry-bulb temperature(Td). - Calculation formula : "Tg = 1. 45 Td - 27. For natural wet-bulb temperature(Tnw), convert the Wet-bulb temperature(Tw) obtained by measurement by the Assmann Psychrometer to the Wet-bulb temperature(Tw) measured in natural state, a use it as Natural wet-bulb temperature(Tnw). If you use HumidCalc, you can easily obtain "Temperature-humidity index(Discomfort Index)", "WBGT(Heat stroke index)", "Dew point temperature", etc. , from weather information. HumidCalc can receive the calculated value of dry bulb temperature (Td) and wet bulb temperature (Tw) from the sister app “Calculator of Air”. You can choose conditions of the wet bulb is you can choose any one of the “Normal" or “Froze” (※ If you choose the “Froze”, setting is enabled in when if sub-zero in wet-bulb temperature(Tw) ). Input range is the temperature is -30 ℃ to 50 ℃ (-22 ° F to 122 ° F), the atmospheric pressure is 600 hPa to 2475 hPa(17. 72 inHg to 73. 09 inHg). If you use this function, you can input "dew point temperature", "relative humidity", etc. (※ there is a need to start up the "Calculator of Air" first). Please input and use the temperature range(0 ℃ to 40 ℃ / 32°F to 104°F ) according to common sense as much as possible. There is a very strong correlation between Globe thermometer temperature(Tg) and Dry-bulb temperature(Td). The natural state here means that the wind speed at the time of measurement is 5 meters per second(16. 4 feet per second) or less. Weight absolute humidity in the more smaller unit. (( Supplementary explanation about the WBGT(Estimated value) and the Discomfort index. The items and indicators that HumidCalc can calculate are as follows.